Product Features
Six filtered functions
Technical Specifications of NSN
Overall Length:
Between 53.215 inches and 55.225 inches
Body Length:
Between 3.460 inches and 3.470 inches
Body Width:
Between 2.930 inches and 2.970 inches
Body Height:
Between 3.170 inches and 3.180 inches
Unthreaded Mounting Hole Diameter:
Between 0.200 inches and 0.220 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 3.860 inches and 3.880 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 2.730 inches and 2.750 inches
Operating Tempurature Range:
-65.0/+165.0 degrees fahrenheit
Operating Tempurature Range:
-65.0 to 165.0 degrees fahrenheit
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference 4th function
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference 6th function
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function:
50.0 ohms 6th radio interference 6th function
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference 5th function
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
1.0 1st radio interference
Operating Current Rating Per Function In Amps:
1.0 3rd radio interference
Operating Current Rating Per Function In Amps:
1.0 4th radio interference
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
Operating Current Rating Per Function In Amps:
1.0 5th radio interference
Operating Current Rating Per Function In Amps:
1.0 6th radio interference
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
1.0 4th radio interference 4th function
Maximum Voltage Drop Per Function:
1.0 volts ac 2nd radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 1st radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 3rd radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 4th radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 5th radio interference
Maximum Voltage Drop Per Function:
350.0 millivolts dc 6th radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 3rd radio interference 3rd function
Maximum Voltage Drop Per Function:
1.0 volts ac 5th radio interference 5th function
Maximum Voltage Drop Per Function:
1.0 volts ac 1st radio interference 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference 4th function
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference 6th function
Input Terminal Identification:
Ms3106e20-7p
Output Terminal Manufacturer Code:
96906
Output Terminal Identification:
Ms3106e20-7p
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 unthreaded hole
Functional Terminal Type And Quantity:
1 connector, plug input 1st function
Functional Terminal Type And Quantity:
1 connector, plug output 2nd function
Maximum Dielectric Withstanding Ac Rms Voltage:
230.0 volts at sea level
Operating Voltage Rating And Type Per Function:
28.0 volts dc 6th radio interference 6th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 5th radio interference 5th function
Maximum Dielectric Withstanding Dc Voltage:
56.0 volts at sea level
Unpackaged Unit Weight:
3.000 pounds
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Filter,power Line
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC